This dataset are about Nafion 112 membrane standard tests and MEA activationtests of PEM fuel cell in various operation condition. Dataset include two general electrochemicalanalysis method, Polarization and Impedance curves. In this dataset, effect of different pressure ofH2/O2 gas, different voltages and various humidity conditions in several steps are considered.Behavior of PEM fuel cell during distinct operation condition tests, activation procedure and different operation conditionbefore and after activation analysis can be concluded from data. In Polarization curves, voltageand power density change as a function of flows of H2/O2 and relative humidity. Resistance of theused equivalent circuit of fuel cell can be calculated from Impedance data. Thus, experimentalresponse of the cell is obvious in the presented data, which is useful in depth analysis, simulationand material performance investigation in PEM fuel cell researches.

For more information about MEA(Membrane Electrode Assembly) activation procedure visithere

Tests

  1. Activation Test MEA Constant Current 0.25A
  2. Activation Test MEA Constant Voltage 0.6V
  3. Activation Test MEA Constant Voltage 0.6V-2
  4. Activation Test MEA Constant Voltage 0.6V-3
  5. Activation Test MEA Constant Voltage 0.6V-4
  6. Activation Test MEA Cycling Potential
  7. Activation Test MEA Standard Protocol
  8. Activation Test MEA Standard Protocol (Repeat)
  9. Standard Test of Nafion Membrane 112


Notebooks

We have provided someJupyter Notebooks to visualize the data, visithere

Issues & Bug Reports

Just fill an issue and describe it. We'll check it ASAP!or send an email todata@ecsim.site.

You can also join our discord server

Discord Channel

Cite

If you use this dataset in your research, we would appreciate citations to the following paper:

Hamidi S, Haghighi S, Askari K. Dataset of Standard Tests of Nafion 112 Membrane and Membrane Electrode Assembly (MEA) Activation Tests of Proton Exchange Membrane (PEM) Fuel Cell. ChemRxiv. 2020; doi:10.26434/chemrxiv.11902023

@article{Hamidi2020,doi ={10.26434/chemrxiv.11902023},url ={https://doi.org/10.26434/chemrxiv.11902023},year ={2020},month = feb,publisher ={American Chemical Society ({ACS})},author ={Sarmin Hamidi and Sepand Haghighi and Kasra Askari},title ={Dataset of Standard Tests of Nafion 112 Membrane and Membrane Electrode Assembly ({MEA}) Activation Tests of Proton Exchange Membrane ({PEM}) Fuel Cell}}

License

Show Your Support

Star This Repo

Give a ⭐️ if this project helped you!

Donate to Our Project

If you do like our project and we hope that you do, can you please support us? Our project is not and is never going to be working for profit. We need the money just so we can continue doing what we do ;-) .

ECSIM Donation


[8]ページ先頭

©2009-2025 Movatter.jp