Movatterモバイル変換


[0]ホーム

URL:


Skip to content

Navigation Menu

Search code, repositories, users, issues, pull requests...

Provide feedback

We read every piece of feedback, and take your input very seriously.

Saved searches

Use saved searches to filter your results more quickly

Sign up

Command line interface (CLI) for WiBeee (old Mirubee) meter.

License

NotificationsYou must be signed in to change notification settings

fquinto/pywibeee

Repository files navigation

Command line interface (CLI) for WiBeee (old Mirubee) meter.

Features

  • Autodiscover the host (IP) of the meter in a network
  • Get version of the meter
  • Get model of the meter
  • Get info of the meter: (version + model + host)
  • Get status meter data
  • Get sensors of the meter
  • Action: reset energy counter
  • Action: reboot of the meter (via web or via special command)
  • Several outputs when recieve data: xml, json, file, plain text
  • 3 methods to get data: async_httpx, async_aiohttp, request

Requirements

pip install xmltodict requests aiohttp httpx

Installation

Install Python CLI packagepywibeee

pip install pywibeee --upgrade

Usage

pywibeee -husage: pywibeee [-h] [-version] (--host HOST| --auto) [-t SETTIMEOUT]                [-o {xml,json,plain,file}]                [-p {80}]                [-m {async_httpx,async_aiohttp,request}]                (-a {reboot,rebootweb,resetenergy}| -g {model,version,status,info,sensors})CLIfor WiBeee (old Mirubee) meteroptional arguments:  -h, --help            show thishelp message andexit  -version, --version   show program's version number and exit  --host HOST           The host (or the IP) of the meter.  --auto                Autodiscover host function, look IP on net.  -t SETTIMEOUT, --settimeout SETTIMEOUT                        set timeout in seconds (default 10)  -o {xml,json,plain,file}, --output {xml,json,plain,file}                        xml|json|plain|file  -a {reboot,rebootweb,resetenergy}, --action {reboot,rebootweb,resetenergy}                        reboot|rebootweb|resetenergy  -g {model,version,status,info,sensors}, --get {model,version,status,info,sensors}                        model|version|status|info|sensors  -p {portnumber}, --port {portnumber}                        port number of the meter (default 80)  -m {async_httpx, async_aiohttp, request}, --method {async_httpx, async_aiohttp, request}                        async_httpx|async_aiohttp|request                        (default async_httpx)Enjoy! :)

Use examples

Get version

$ pywibeee --host 192.168.1.150 --get version{"response": {"webversion":"3.4.614"}}

Get model

$ pywibeee --host 192.168.1.150 --get model{"response": {"model":"WBB","model_description":"Wibeee BOX"}}

Get info

$ pywibeee --host 192.168.1.150 -g info{"response": {"model":"WBB","model_description":"Wibeee BOX","webversion":"3.4.614","host":"192.168.1.150"}}

Get sensors with autodiscover

$ pywibeee --auto -g sensors{"vrms": ["Vrms", "V", "mdi:power-plug"], "irms": ["Irms", "A", "mdi:flash-auto"], "p_aparent": ["Apparent Power", "VA", "mdi:flash-circle"], "p_activa": ["Active Power", "W", "mdi:flash"], "p_reactiva_ind": ["Inductive Reactive Power", "VArL", "mdi:flash-outline"], "p_reactiva_cap": ["Capacitive Reactive Power", "VArC", "mdi:flash-outline"], "frecuencia": ["Frequency", "Hz", "mdi:current-ac"], "factor_potencia": ["Power Factor", " ", "mdi:math-cos"], "energia_activa": ["Active Energy", "Wh", "mdi:pulse"], "energia_reactiva_ind": ["Inductive Reactive Energy", "VArLh", "mdi:alpha-e-circle-outline"], "energia_reactiva_cap": ["Capacitive Reactive Energy", "VArCh", "mdi:alpha-e-circle-outline"], "angle": ["Angle", "\u00b0", "mdi:angle-acute"], "thd_total": ["THD Current", "%", "mdi:chart-bubble"], "thd_fund": ["THD Current (fundamental)", "A", "mdi:vector-point"], "thd_ar3": ["THD Current Harmonic 3", "A", "mdi:numeric-3"], "thd_ar5": ["THD Current Harmonic 5", "A", "mdi:numeric-5"], "thd_ar7": ["THD Current Harmonic 7", "A", "mdi:numeric-7"], "thd_ar9": ["THD Current Harmonic 9", "A", "mdi:numeric-9"], "thd_tot_V": ["THD Voltage", "%", "mdi:chart-bubble"], "thd_fun_V": ["THD Voltage (fundamental)", "V", "mdi:vector-point"], "thd_ar3_V": ["THD Voltage Harmonic 3", "V", "mdi:numeric-3"], "thd_ar5_V": ["THD Voltage Harmonic 5", "V", "mdi:numeric-5"], "thd_ar7_V": ["THD Voltage Harmonic 7", "V", "mdi:numeric-7"], "thd_ar9_V": ["THD Voltage Harmonic 9", "V", "mdi:numeric-9"]}

Get status

$ pywibeee --host 192.168.1.150 --get status{"response": {"model": "WBB", "webversion": "3.4.614", "time": "1570484447", "fase1_vrms": "228.70", "fase1_irms": "1.59", "fase1_p_aparent": "362.65", "fase1_p_activa": "264.34", "fase1_p_reactiva_ind": "0.00", "fase1_p_reactiva_cap": "248.27", "fase1_frecuencia": "50.08", "fase1_factor_potencia": "-0.729", "fase1_energia_activa": "222157", "fase1_energia_reactiva_ind": "4631", "fase1_energia_reactiva_cap": "188269", "fase1_angle": "0.00", "fase1_thd_total": "64.60", "fase1_thd_fund": "1.40", "fase1_thd_ar3": "0.60", "fase1_thd_ar5": "0.50", "fase1_thd_ar7": "0.40", "fase1_thd_ar9": "0.40", "fase1_thd_tot_V": "0.00", "fase1_thd_fun_V": "228.50", "fase1_thd_ar3_V": "0.00", "fase1_thd_ar5_V": "0.00", "fase1_thd_ar7_V": "0.00", "fase1_thd_ar9_V": "0.00", "fase2_vrms": "228.70", "fase2_irms": "0.34", "fase2_p_aparent": "76.77", "fase2_p_activa": "50.99", "fase2_p_reactiva_ind": "0.00", "fase2_p_reactiva_cap": "0.00", "fase2_frecuencia": "50.08", "fase2_factor_potencia": "-0.664", "fase2_energia_activa": "47714", "fase2_energia_reactiva_ind": "5021", "fase2_energia_reactiva_cap": "641", "fase2_angle": "0.00", "fase2_thd_total": "0.00", "fase2_thd_fund": "0.00", "fase2_thd_ar3": "0.00", "fase2_thd_ar5": "0.00", "fase2_thd_ar7": "0.00", "fase2_thd_ar9": "0.00", "fase2_thd_tot_V": "0.00", "fase2_thd_fun_V": "228.50", "fase2_thd_ar3_V": "0.00", "fase2_thd_ar5_V": "0.00", "fase2_thd_ar7_V": "0.00", "fase2_thd_ar9_V": "0.00", "fase3_vrms": "228.70", "fase3_irms": "1.53", "fase3_p_aparent": "349.48", "fase3_p_activa": "265.40", "fase3_p_reactiva_ind": "0.00", "fase3_p_reactiva_cap": "227.37", "fase3_frecuencia": "50.08", "fase3_factor_potencia": "0.759", "fase3_energia_activa": "187069", "fase3_energia_reactiva_ind": "196", "fase3_energia_reactiva_cap": "159927", "fase3_angle": "0.00", "fase3_thd_total": "66.10", "fase3_thd_fund": "1.30", "fase3_thd_ar3": "0.60", "fase3_thd_ar5": "0.50", "fase3_thd_ar7": "0.40", "fase3_thd_ar9": "0.00", "fase3_thd_tot_V": "0.00", "fase3_thd_fun_V": "228.50", "fase3_thd_ar3_V": "0.00", "fase3_thd_ar5_V": "0.00", "fase3_thd_ar7_V": "0.00", "fase3_thd_ar9_V": "0.00", "fase4_vrms": "228.70", "fase4_irms": "3.45", "fase4_p_aparent": "788.90", "fase4_p_activa": "49.93", "fase4_p_reactiva_ind": "0.00", "fase4_p_reactiva_cap": "20.90", "fase4_frecuencia": "50.08", "fase4_factor_potencia": "-0.063", "fase4_energia_activa": "456941", "fase4_energia_reactiva_ind": "9849", "fase4_energia_reactiva_cap": "348839", "scale": "100", "coilStatus": null, "ground": "0.00", "model_description": "Wibeee BOX"}}

Notes

  • Default IP for WiBeee (old Mirubee): 192.168.1.150
  • Default usernames / passwords:
    • Basic:user / user
    • Admin:admin / Sm1l1cs?
    • Admin another:admin / Wib333?
  • MAC Address: 00:1E:C0 (Microchip Technology)

OTA comands

  • 21001A 576246696E697368426F6F746C6F6164657250726F6363657373 0D0A (hex) =WbStartBootloaderProccess = CHANGE_PORT_COMMAND_INIT
  • 200119 576246696e697368426f6f746c6f6164657250726f6363657373 0D0A (hex) =WbFinishBootloaderProccess = CHANGE_PORT_COMMAND_FINAL
  • 0D (hex) = Enter key = get version
  • 0F (hex) = read Backup Position
  • 01 (hex) = reset

Last firmware

Tools for firmware and App investigation

  • Emulator of WiBeee product:emulator
  • Cloud server for WiBeee called webserver:webserver

With this tools you can "play" with the firmware and the app.

Open ports

80/tcp  open http      Microchip Libraries of Applications TCP/IP Stack httpd502/tcp open modbus    Modbus TCP550/tcp open new-rwho?

Models description WiBeee

  • WBM = Wibeee 1Ph
  • WBT = Wibeee 3Ph
  • WMX = Wibeee MAX
  • WTD = Wibeee 3Ph RN
  • WX2 = Wibeee MAX 2S
  • WX3 = Wibeee MAX 3S
  • WXX = Wibeee MAX MS
  • WBB = Wibeee BOX
  • WB3 = Wibeee BOX S3P
  • W3P = Wibeee 3Ph 3W
  • WGD = Wibeee GND
  • WBP = Wibeee SMART PLUG

Installation alternatives (getting latest source code)

If you want to install latest source code:

pip install git+http://github.com/fquinto/pywibeee

or

git clone git://github.com/fquinto/pywibeeecd pywibeeepython setup.py install

Changelog

Future development

  • Improve another models.

License

GNU General Public License version 2