IEEE standard on interconnection of distributed generation resources into the power grid

IEEE 1547 (Standard for Interconnecting Distributed Resources with Electric Power Systems) is a standard of theInstitute of Electrical and Electronics Engineers meant to provide a set of criteria and requirements for the interconnection ofdistributed generation resources into thepower grid.

Purpose

[edit]

"This document provides a uniform standard for interconnection of distributed resources with EPSs [Electric Power Systems]. It provides requirements relevant to the performance, operation, testing, safety, and maintenance of the interconnection."[1]

With the increased adoption of distributed resources in the present and future, a set of standards regarding their usage in the grid becomes increasingly important for the overall reliability, safety, and cost. Furthermore, the lack of a concrete national standard was seen as a roadblock to the implementation of new distributed generation projects. The standard is intended to be universally adoptable, technology-neutral, and cover distributed resources as large 10MVA.

Development

[edit]

In early 1999, the IEEE approved the undertaking of P1547. With the support of theUnited States Department of Energy, the project was initiated on a fast-track basis, which would halve the usual development time. The draft standard was revised 10 times before P1547/Draft 11 was approved with a 91% vote in February 2003. It was then approved by the IEEE Standards Board on June 12, 2003, and received anANSI designation on October 20, 2003.[2]

Risk of System Disturbance

[edit]

IEEE 1547-2003 had a tight underfrequency protection setting of 59.3 Hz which posed a risk for grid stability. In case of an underfrequency situation,[3] e.g. after a major loss of generation, the situation may get worse when a multitude ofdistributed energy resources (DER) disconnect simultaneously. IEEE 1547-2003 demanded also an obligatory overfrequency disconnection at 60.5 Hz. With a rising share of distributed generation there is a possibility of triggering a non-linearoscillator in the multiGW range within the transmission grid. In Europe, this problem with similar standards has already been addressed byENTSO-E.[4] IEEE 1547-2018 now allows operation from 56.5Hz to 62Hz with frequency droop included.

Energy Policy Act of 2005

[edit]

"Interconnection services shall be offered based upon the standards developed by the Institute of Electrical and Electronics Engineers: IEEE Standard 1547 for Interconnecting Distributed Resources With Electric Power Systems, as they may be amended from time to time."[5]

TheEnergy Policy Act of 2005 established IEEE 1547 as the national standard for the interconnection of distributed generation resources in theUnited States of America.

Related Standards

[edit]

Currently, there are six complementary standards designed to expand upon or clarify the initial standard, two of which are published, and the other four still in the draft phase.

  • IEEE 1547.1, published in 2005 andupdated in May 2020, further describes the testing of the interconnection in order to determine whether or not it conforms to standards.
  • IEEE 1547.2, published in 2008, provides a technical background on the standard.
  • IEEE P1547.3, draft in progress, details cyber security guidelines.
  • IEEE 1547.4, published in 2011, is a guide for the design, operation, and integration of conforming systems.
  • IEEE 1547.6, published in 2011, describes practices for secondary network interconnections.
  • IEEE 1547.7, published in 2013, provides distribution impact studies for distributed resource interconnection.
  • IEEE P1547.9, draft in progress, details energy storage guidelines
  • IEEE 1547-2018, published in 2018, IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces. Revision to IEEE 1547-2003

See also

[edit]

References

[edit]
  1. ^Vaughn (2007-12-21)."IEEE SCC21 1547 Home Page". IEEE. Retrieved2008-01-26.
  2. ^Thomas Basso and N. Richard Friedman (November 2003)."IEEE 1547 National Standard for Interconnecting Distributed Generation: How Could It Help My Facility?"(PDF). Distributed Energy. Retrieved2011-08-28.
  3. ^E. Grebe, D. Klaar; et al. (April 2004)."Final Report of the Investigation Committee on the 28 September 2003 Blackout in Italy"(PDF). Brussels:UCTE. Retrieved2011-08-28.Please compare with Chapter 6.3.5 and 6.4.1: "For instance, due to its significant penetration level, the effect of the distributed generation may no longer be neglected and appropriate technical requirements need to be defined." p. 94
  4. ^Letter, 18 July 2011 from Mr. Dobbeni, President of ENTSO-E to Mr Oettinger, European Commissioner for Energy
  5. ^"Energy Policy Act of 2005 SEC 1254"(PDF). August 5, 2005. Archived fromthe original(PDF) on December 1, 2007. Retrieved2008-01-26.

External links

[edit]
  • IEEE (IEEE 1547 Homepage)
Current
802 series
802
802.1
802.3
(Ethernet)
802.11
(Wi-Fi)
802.15
Proposed
Superseded
Retrieved from "https://en.wikipedia.org/w/index.php?title=IEEE_1547&oldid=1237710886"
Categories:
Hidden categories:

[8]ページ先頭

©2009-2025 Movatter.jp