From Wikipedia, the free encyclopedia
(Redirected fromDicrotic pulse)
Tactile arterial palpation of the heartbeat by fingertips
This article is about heartbeats. For other uses, seePulse (disambiguation).
This articleneeds additional citations forverification. Please helpimprove this article byadding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Pulse" – news ·newspapers ·books ·scholar ·JSTOR
(December 2008) (Learn how and when to remove this message)
Pulse
Diagram of the rise and lower of blood from a pulse.
OrganismsAnimalia*
Biological systemCirculatory system
ActionInvoluntary
MethodHeart pumps blood usingreciprocating method causing inconstant blood flow throughout the circulatory system that can be recognized. (SeeCardiac cycle)
Frequency60–100 per minute (humans)
Duration0.6–1 second (humans)
Animalia with the exception ofPorifera,Cnidaria,Ctenophora,Platyhelminthes,Bryozoan,Amphioxus.

Inmedicine, thepulse is the rhythmic pulsations ofarteries in response to thecardiac cycle (heartbeat).[1] The pulse may bepalpated in any place that allows an artery to be compressed near the surface of the body, such as at theneck (carotid artery),wrist (radial artery orulnar artery), at thegroin (femoral artery), behind theknee (popliteal artery), near theankle joint (posterior tibial artery), and on foot (dorsalis pedis artery).[2][1] The pulse is most commonly measured at the wrist or neck.[3] Asphygmograph is an instrument for measuring the pulse.[4]

Physiology

[edit]
Pulse evaluation at the radial artery.
Recommended points to evaluate pulse

ClaudiusGalen was perhaps the firstphysiologist to describe the pulse.[5] The pulse is an expedienttactile method of determination ofsystolicblood pressure to a trained observer.Diastolic blood pressure is non-palpable and unobservable by tactile methods, occurring between heartbeats.

Pressure waves generated by the heart insystole move the arterial walls. Forward movement ofblood occurs when the boundaries are pliable and compliant. These properties form enough to create a palpable pressure wave.

Pulse velocity, pulse deficits and much more physiologic data are readily and simplistically visualized by the use of one or morearterial catheters connected to atransducer andoscilloscope. This invasive technique has been commonly used inintensive care since the 1970s.

The pulse may be further indirectly observed under light absorbances of varying wavelengths with assigned and inexpensively reproduced mathematical ratios. Applied capture of variances of light signal from the blood componenthemoglobin under oxygenated vs. deoxygenated conditions allows the technology ofpulse oximetry.

Characteristics

[edit]

Rate

[edit]

Further information:Heart rate

The rate of the pulse can be observed and measured on the outside of an artery by tactile or visual means. It is recorded as arterial beats per minute or BPM. Although the pulse and heart beat are related, they are not the same. For example, there is a delay between the onset of the heart beat and the onset of the pulse, known as thepulse transit time, which varies by site. Similarly measurements ofheart rate variability and pulse rate variability differ.[6]

In healthy people, the pulse rate is close to theheart rate, as measured byECG.[6] Measuring the pulse rate is therefore a convenient way to estimate the heart rate.[7]Pulse deficit is a condition in which a person has a difference between their pulse rate and heart rate. It can be observed by simultaneouspalpation at theradial artery andauscultation using astethoscopeat the PMI, near the heart apex, for example. Typically, in people with pulse deficit, heart beats do not result in pulsations at the periphery, meaning the pulse rate is lower than the heart rate. Pulse deficit has been found to be significant in the context ofpremature ventricular contraction[citation needed] andatrial fibrillation.[8]

Rhythm

[edit]

A normal pulse is regular in rhythm and force. An irregular pulse may be due tosinus arrhythmia,ectopic beats,atrial fibrillation,paroxysmal atrial tachycardia,atrial flutter,partial heart block etc. Intermittent dropping out of beats at pulse is called "intermittent pulse". Examples ofregular intermittent (regularly irregular) pulse includepulsus bigeminus,second-degree atrioventricular block. An example ofirregular intermittent (irregularly irregular) pulse isatrial fibrillation.

Volume

[edit]

The degree of expansion displayed by artery during diastolic and systolic state is called volume. It is also known as amplitude, expansion or size of pulse.

Hypokinetic pulse

[edit]

A weak pulse signifies narrowpulse pressure. It may be due to lowcardiac output (as seen inshock,congestive cardiac failure),hypovolemia,valvular heart disease (such asaortic outflow tract obstruction,mitral stenosis,aortic arch syndrome) etc.

Hyperkinetic pulse

[edit]

A bounding pulse signifies high pulse pressure. It may be due to lowperipheral resistance (as seen infever,anemia,thyrotoxicosis,hyperkinetic heart syndrome [de],A-V fistula,Paget's disease,beriberi,liver cirrhosis), increased cardiac output, increasedstroke volume (as seen in anxiety, exercise,complete heart block,aortic regurgitation), decreased distensibility of arterial system (as seen inatherosclerosis,hypertension andcoarctation of aorta).

The strength of the pulse can also be reported:[9][10]

  • 0 = Absent
  • 1 = Barely palpable
  • 2 = Easily palpable
  • 3 = Full
  • 4 = Aneurysmal orbounding pulse

Force

[edit]

Also known as compressibility of pulse. It is a rough indication ofsystolic blood pressure.

Tension

[edit]

Determined mainly by mean arterial blood pressure; corresponds todiastolic blood pressure. A low tension pulse (pulsus mollis), the vessel is soft or impalpable between beats. In high tension pulse (pulsus durus), vessels feel rigid even between pulse beats.

Form

[edit]

A form or contour of a pulse is palpatory estimation ofarteriogram. A quickly rising and quickly falling pulse (pulsus celer) is seen in aortic regurgitation. A slow rising and slowly falling pulse (pulsus tardus) is seen in aortic stenosis.

Equality

[edit]

Comparing pulses and different places gives valuable clinical information.

A discrepant or unequal pulse between left and right radial artery is observed in anomalous or aberrant course of artery, coarctation of aorta,aortitis,dissecting aneurysm,peripheral embolism etc. An unequal pulse between upper and lower extremities is seen in coarctation to aorta, aortitis, block atbifurcation of aorta,dissection of aorta,iatrogenic trauma andarteriosclerotic obstruction.

Condition of arterial wall

[edit]

A normal artery is not palpable after flattening bydigital pressure. A thick radial artery which is palpable 7.5–10 cm up the forearm is suggestive of arteriosclerosis.

Radio-femoral delay

[edit]

In coarctation of aorta, femoral pulse may be significantly delayed as compared to radial pulse (unless there is coexisting aortic regurgitation). The delay can also be observed insupravalvar aortic stenosis.

Patterns

[edit]

Several pulse patterns can be of clinical significance. These include:

  • Anacrotic pulse: notch on the upstroke of the carotid pulse. Two distinct waves (slow initial upstroke and delayed peak, which is close to S2). Present in AS.
  • Dicrotic pulse: is characterized by two beats per cardiac cycle, one systolic and the other diastolic. Physiologically, the dicrotic wave is the result of reflected waves from the lower extremities and aorta. Conditions associated with low cardiac output and high systemic vascular resistance can produce a dicrotic pulse.[11][12]
  • Pulse deficit: difference in the heart rate by direct cardiac ausculation and by palpation of the peripheral arterial pulse rate when in atrial fibrillation (AF).
  • Pulsus alternans: an ominous medical sign that indicates progressive systolic heart failure. To trained fingertips, the examiner notes a pattern of a strong pulse followed by a weak pulse over and over again. This pulse signals a flagging effort of the heart to sustain itself in systole. It also can be detected in HCM with obstruction.
  • Pulsus bigeminus: indicates a pair of hoofbeats within each heartbeat. Concurrentauscultation of the heart may reveal agallop rhythm of the native heartbeat.
  • Pulsus bisferiens: is characterized by two beats per cardiac cycle, both systolic, unlike the dicrotic pulse. It is an unusual physical finding typically seen in patients with aortic valve diseases if the aortic valve does not normally open and close. Trained fingertips will observe two pulses to each heartbeat instead of one.
  • Pulsus tardus et parvus, alsopulsus parvus et tardus, slow-rising pulse and anacrotic pulse, is weak (parvus), and late (tardus) relative to its expected characteristics. It is caused by a stiffened aortic valve that makes it progressively harder to open, thus requiring increased generation of blood pressure in the left ventricle. It is seen inaortic valve stenosis.[12][13][14][15]
  • Pulsus paradoxus: a condition in which some heartbeats cannot be detected at the radial artery during the inspiration phase of respiration. It is caused by an exaggerated decrease in blood pressure during this phase, and is diagnostic of a variety of cardiac and respiratory conditions of varying urgency, such ascardiac tamponade.
  • Tachycardia: an elevated resting heart rate. In general anelectrocardiogram (ECG) is required to identify the type of tachycardia.
  • Pulsatile This description of the pulse implies the intrinsic physiology ofsystole anddiastole. Scientifically, systole and diastole areforces that expand and contract the pulmonary and systemic circulations.
  • A collapsing pulse is a sign ofhyperdynamic circulation, which can be seen in AR or PDA.

Common palpable sites

[edit]

Sites can be divided into peripheral pulses and central pulses. Central pulses include the carotid and femoral pulses.[2]

Upper limb

[edit]
Front of right upper extremity
  • Axillary pulse: located inferiorly of the lateral wall of theaxilla
  • Brachial pulse: located on the inside of the upper arm near the elbow, frequently used in place of carotid pulse in infants (brachial artery)
  • Radial pulse: located on the lateral of the wrist (radial artery). It can also be found in theanatomical snuff box. Commonly, the radial pulse is measured with three fingers. The finger closest to the heart is used to occlude thepulse pressure, the middle finger is used get a crude estimate of theblood pressure, and the finger most distal to the heart (usually the ring finger) is used to nullify the effect of theulnar pulse as the two arteries are connected via the palmar arches (superficial anddeep).[citation needed]
  • Ulnar pulse: located on the medial of the wrist (ulnar artery).

Lower limb

[edit]
  • Femoral pulse: located in the inner thigh, at themid-inguinal point, halfway between the pubic symphysis and anterior superior iliac spine (femoral artery).
  • Popliteal pulse: Above the knee in the popliteal fossa, found by holding the bent knee. The patient bends the knee at approximately 124°, and the health care provider holds it in both hands to find the popliteal artery in the pit behind the knee (popliteal artery).
  • Dorsalis pedis pulse: located on top of the foot, immediately lateral to the extensor of hallucis longus (dorsalis pedis artery).
  • Tibialis posterior pulse: located on the medial side of the ankle, 2 cm inferior and 2 cm posterior to the medial malleolus (posterior tibial artery). It is easily palpable overPimenta's Point.

Head and neck

[edit]
Arteries of the neck.
  • Carotid pulse: located in the neck (carotid artery). The carotid artery should be palpated gently and while the patient is sitting or lying down. Stimulating its baroreceptors with low palpitation can provoke severebradycardia or even stop the heart in some sensitive persons. Also, a person's two carotid arteries should not be palpated at the same time. Doing so may limit the flow of blood to the head, possibly leading tofainting or brainischemia. It can be felt between the anterior border of the sternocleidomastoid muscle, above the hyoid bone and lateral to the thyroid cartilage.
  • Facial pulse: located on the mandible (lower jawbone) on a line with the corners of the mouth (facial artery).
  • Temporal pulse: located on thetemple directly in front of the ear (superficial temporal artery).

Although the pulse can be felt in multiple places in the head, people should not normally hear their heartbeats within the head. This is calledpulsatile tinnitus, and it can indicate several medical disorders.

Torso

[edit]
  • Apical pulse: located in the 5th left intercostal space, 1.25 cm lateral to themid-clavicular line. In contrast with other pulse sites, the apical pulse site is unilateral, and measured not under an artery, but below theheart itself (more specifically, the apex of the heart). See alsoapex beat.

History

[edit]

Pulse rate was first measured by ancient Greek physicians and scientists. The first person to measure the heart beat wasHerophilus of Alexandria,Egypt (c. 335–280 BC) who designed a water clock to time the pulse.[16]Rumi has mentioned in a poem that "The wise physician measured the patient's pulse and became aware of his condition." It shows the practice was common during Rumi's era and geography.[17] The first person to accurately measure the pulse rate wasSantorio Santorii who invented thepulsilogium, a form ofpendulum which was later studied byGalileo Galilei.[18] A century later another physician,de Lacroix, used the pulsilogium to test cardiac function.

See also

[edit]

References

[edit]
Wikimedia Commons has media related toPulse.
  1. ^ab"pulse".The Free Dictionary.
  2. ^abBerg, Dale; Worzala, Katherine (2006).Atlas of Adult Physical Diagnosis. Lippincott Williams & Wilkins. p. 80.ISBN 9780781741903.Archived from the original on 2023-07-03. Retrieved2020-10-03.
  3. ^"Pulse".MedlinePlus Medical Encyclopedia. Retrieved25 November 2024.
  4. ^"sphygmograph".The Free Dictionary.
  5. ^Temkin 165;BBC[a]
  6. ^abYuda, Emi; Yamamoto, Kento; Yoshida, Yutaka; Hayano, Junichiro (21 February 2020)."Differences in pulse rate variability with measurement site".Journal of Physiological Anthropology.39 (1): 4.doi:10.1186/s40101-020-0214-1.ISSN 1880-6791.PMC 7035641.PMID 32085811.
  7. ^"Pulse Rate Measurement".Healthwise. WebMD.Archived from the original on 23 July 2012. Retrieved14 March 2011.
  8. ^Karadavut, Serhat; Altintop, Ismail (30 November 2021)."Pulse deficit in atrial fibrillation — a different perspective on rhythm or rate control strategy".Kardiologia Polska.79 (11):1231–1238.doi:10.33963/KP.a2021.0107.PMID 34506629.
  9. ^"www.meddean.luc.edu".Archived from the original on 2008-09-07. Retrieved2009-05-20.
  10. ^"Vascular Surgery, University of Kansas School of Medicine". Archived fromthe original on 2009-02-04. Retrieved2009-05-20.
  11. ^Dennis, Mark; Bowen, William Talbot; Cho, Lucy (2016).Mechanisms of Clinical Signs – EPub3. Elsevier Health Sciences. p. 177.ISBN 9780729585613.Archived from the original on 2023-07-03. Retrieved2018-01-02.
  12. ^abMcGee, Steven (2016).Evidence-Based Physical Diagnosis E-Book. Elsevier Health Sciences. pp. 105–106.ISBN 9780323508711.Archived from the original on 2023-07-03. Retrieved2018-01-02.
  13. ^Li JC, Yuan Y, Qin W, et al. (April 2007)."Evaluation of the tardus-parvus pattern in patients with atherosclerotic and nonatherosclerotic renal artery stenosis".J Ultrasound Med.26 (4):419–26.doi:10.7863/jum.2007.26.4.419.PMID 17384038.S2CID 11562194.Archived from the original on 2020-05-10. Retrieved2018-01-02.
  14. ^Toy, Eugene, et al.Case Files: Internal Medicine. McGraw-Hill Companies, Inc. 2007. Page 43.ISBN 0-07-146303-8.
  15. ^Sanders, Roger C.; Winter, Thomas Charles (2007).Clinical Sonography: A Practical Guide. Lippincott Williams & Wilkins. p. 219.ISBN 9780781748698.Archived from the original on 2023-07-03. Retrieved2018-01-02.
  16. ^Hajar, R. (2018)."The Pulse from Ancient to Modern Medicine".Heart Views.19 (3):117–120.doi:10.4103/HEARTVIEWS.HEARTVIEWS_16_19.PMC 6448473.PMID 31007864.
  17. ^"Rumi poem on the afflicted patient".Archived from the original on 2022-12-16. Retrieved2022-12-16.
  18. ^Bigotti, Fabrizio; Taylor, David (2017)."The Pulsilogium of Santorio: New Light on Technology and Measurement in Early Modern Medicine".Societate Si Politica.11 (2):53–113.ISSN 1843-1348.PMC 6407692.PMID 30854144.

External links

[edit]
Medical history
Physical examination
General/IPPA
Vital signs
HEENT
Respiratory
Cardiovascular
Abdominal
Musculoskeletal
Neurological
Neonatal
Gynecological
Sports
Assessment and plan
Heart
Cardiac output
Ultrasound
Heart rate
Conduction
Chamber pressure
Other
Vascular system/
hemodynamics
Blood flow
Blood pressure
Regulation of BP
Chest pain
Auscultation
Pulse
Other
Shock
Cardiovascular disease
Aortic insufficiency
Otherendocardium
Pericardium
Other
Vascular disease
Arterial
Venous