Concrete cover, inreinforced concrete, is the least distance between the surface of embeddedreinforcement and the outer surface of theconcrete (ACI 130). The concrete cover depth can be measured with acover meter. The purpose of concrete cover is to protect the reinforcement from corrosion, fire, and other potential damage.
The required concrete cover depends on several factors, including the environmental conditions to which the structure will be exposed, the size of the reinforcing steel, the concrete strength, and the type of structure being constructed. Generally, larger diameter reinforcement bars require more concrete cover than smaller ones.
In most cases, local building codes and engineering standards specify the minimum required concrete cover for various types of structures. It is important to adhere to these requirements to ensure the safety and longevity of the structure.
The concrete cover must have a minimum thickness for three main reasons:
The premature failure of corroded steel reinforcements and the expansion of the iron corrosion products around the rebars are amongst the main causes of the concrete degradation. Thecarbon steel of rebars is protected from oxidation by atmosphericoxygen by the highpH of concrete interstitial water. Iron bar surface ispassivated as long as the pH value is higher than 10.5. Fresh cement water has a pH of about 13.5 while evolved cement water pH ~ 12.5 is controlled by the dissolution ofcalcium hydroxide (portlandite).Carbon dioxide present in the air slowly diffuses through the concrete cover over the rebar and progressively reacts with the alkaline hydroxides (KOH,NaOH) and with calcium hydroxide leading to thecarbonatation of the hydrated cement paste. As a result, the pH of the cement drops and when its value is below 10.5 – 9.5, steel surface is no longer passivated and starts to corrode. A sufficient thickness of concrete cover is thus required in order to slow down the carbonatation process towards the rebar. The minimum concrete cover will depend on the environmental conditions encountered and must be thicker when the concrete is also exposed to moisture andchloride (proximity to the sea, use of de-icing salt for bridges or roads, ...). A high quality concrete made with a low water-to-cement (w/c) ratio will have a lowerporosity and will be less permeable to water and to the ingress of corrosive species (dissolved oxygen, chloride, ...). A thicker cover or a more compact concrete will also reduce the diffusion of CO2 in the concrete, protecting it better from carbonatation and maintaining a higher pH for a longer time period, increasing so the rebar service life.
Concrete covers are frequently used in the construction of commercial developments, homes, bridges, municipalities, curb forming, and other locations or projects requiring long-lasting,durability.[2] Concrete and steel reinforcement bars combine to create strong, resilient structures in the following ways:
Nationalcodes also specify minimum cover requirements based on their respective local exposure conditions.
| Country | Concrete Code | Range of Concrete Cover (mm) |
|---|---|---|
| UK | BS:8110 | 25-50 |
| EU | EN 1992 (EC2) | diameter +10 - 55 |
| USA | ACI:318 | 40-75 |
| Australia | AS:3600 | 15-78 |
| India | IS 456 (2000) | 20-75 |
Large cover depths (50–75 mm) are required to protect reinforcement against corrosion in aggressive environments, but thick cover leads to increasedcrack widths inflexural reinforced concrete members. Large crack-widths (greater than 0.3 mm) permit ingress of moisture and chemical attack to the concrete, resulting in possible corrosion of reinforcement anddeterioration of concrete. Therefore, thick covers defeat the very purpose for which it is provided. There is a need for judicious balance of cover depth and crack width requirements.
A possible economical solution for this paradox is the placing of a second layer ofcorrosion-resistant reinforcement likestainless steel rebars ormeshes orFRP rebars in the concrete cover to distribute the cracks.