Launch-type boiler

From Wikipedia, the free encyclopedia
(Redirected fromBagnall boiler)
This articleneeds additional citations forverification. Please helpimprove this article byadding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Launch-type boiler" – news ·newspapers ·books ·scholar ·JSTOR
(February 2010) (Learn how and when to remove this message)
Germansemi-portable engine, with boiler firebox withdrawn for servicing

Alaunch-type,gunboat orhorizontal multitubular boiler[1] is a form of smallsteam boiler. It consists of a cylindrical horizontal shell with a cylindrical furnace andfire-tubes within this.

Their name derives from the boiler's popular use at one time for smallsteam yachts andlaunches. They have also been used in some early Navaltorpedo boat destroyers.

Description

[edit]
End-on view of the furnace, showing the small steam space above

The cylindrical furnace or firebox fits entirely within the boiler's outer shell. Unlike thelocomotive boiler, there is no firebox grate emerging beneath the main boiler. The boiler has similarities with both the locomotive boiler (the multiple small fire-tubes), and theScotch marine boiler (the short cylindrical furnace). As a fire-tube boiler it has generous heating area and so is an effective steamer. Firebox construction is also simpler, thus cheaper, than for the locomotive firebox. As the circular furnace is largely self-supporting against boiler pressure, it did not require the extensive and costlystays of the locomotive boiler. This also allowed the boiler to be made with a bolted joint in the outer shell and so the whole furnace and tube nest could be withdrawn for inspection and maintenance.

The firebox is of limited size though, and unlike the locomotive boiler cannot expand beyond the size of the boiler shell. This limits the sustained output that is possible.[2] The grate and ashpan are also limited in size, the grate being a set of bars part-way across the furnace tube and the ashpan the restricted space beneath this. These features limit the boiler's ability to burn hardbituminous coal and they require a supply of Welshsteam coal, or similar, instead. Firing with wood orbiomass fuels was difficult. Firebox capacity is further restricted by the space used for the ashpan and also by the dry-back furnace.[2] The small ashpan also restricts their ability to steam for long periods.

One drawback of the boiler was the large diameter of the furnace relative to the boiler shell, and thus the small steam space above the crown of the furnace. This made the boilers prone topriming, particularly on a rough sea, where water could be carried over into the steam pipe.

A more serious danger was the limited reserve of the water level, where the water level had only to drop by a small amount owing to inattention before the furnace crown would be exposed, with likely overheating and risk of boiler explosion. The boiler was safe when correctly fired, but could not be left unattended. These water level restrictions became even more troublesome when the boiler was tilted, even by as little as a steep railway line. An unusual rate of wear and number of replacement furnaces supplied for the Heywood locomotives has been put down to this cause.[2]

The boiler did see some popularity in mainland Europe, as a boiler for smallportable engines. A similar boiler, but arranged with return fire-tubes, was built in America as theHuber boiler.

Bagnall boiler

[edit]
Early semi-portable engine, 1860s, with enlarged furnace

To reduce the limitations of the small furnace, an enlarged form was developed. The area of the boiler shell alongside the furnace was enlarged in diameter, but remained circular. This permitted a larger diameter of furnace to be fitted. The firebox section of the shell was offset downwards, so that the tube nest from the upper part of the furnace was in the lowest, water-filled, portion of the shell. As the plates were still cylindrical they did not require stays, but there may have been a few small rod stays to support the flat part of the throatplate between the two sections of the shell.[3]

This boiler design was used for semi-portable engines from the 1860s. As the wider grate allowed the burning of poor fuels, such as straw or sugarcane waste, it was favoured for agricultural use and was widely known as the 'colonial' type.Marshalls built many of these and patented the design as their 'Britannia' firebox.[4] This was also offered in a lengthened form as a log-burning furnace, particularly for use in Australia and Africa where forest land was being clear-felled for agriculture.[5]

All-circular launch boilers (rather than locomotive boilers) were not widely used in coal-rich Britain, apart from these enlarged types. They were sometimes known as 'marine' boilers, although this enlarged form was not favoured for marine use, owing to its raised centre of gravity.

Bagnall railway locomotives

[edit]
Small Bagnallcontractor's loco

The enlarged circular firebox was also used byW. G. Bagnall for narrow-gauge locomotives, from 1890.[3]

One of the last of these to be built, the last industrial narrow-gauge steam locomotive to be built for use in the UK, wasMonarch, an articulated locomotive built in 1953 forBowaters Paper Railway in Kent. This was originally built for the2 ft sugar plantation railways in South Africa, but re-gauged to2 ft 6 in. These were articulated toBagnall's modified Meyer design. The originalMeyer locomotive used two articulated bogies beneath a tank locomotive frame carrying the boiler and water tanks. This limited the space available for the firebox, a disadvantage which could be avoided, for small locos, by the use of Bagnall's boiler with a circular firebox entirely above the frames.

Railway locomotives

[edit]
LocomotiveEffie onSir Arthur Heywood'sDuffield Bank Railway
Dot, from theGorton Foundry works railway

Launch-type boilers were only rarely used for railwaylocomotives, although they were notably used bySir Arthur Heywood from 1874 for his15 in (381 mm)minimum-gauge railways atDuffield Bank andEaton Hall.[6]

Other minimum-gauge railways, notable the18 in (457 mm) gauge works railways atCrewe,Horwich and theGuinness brewery in Dublin, also used launch-type boilers, owing to the limited space between the frames for a conventional firebox.

Heywood-designedUrsula at thePerrygrove Railway, showing the limited grate and ashpan size.

A limitation of this design for steam locomotives was the need to fit fire, grate and ashpan all within the confined circular furnace tube. This limited the radiative heating surface of the furnace, and thus the immediate steam-raising power of the boiler. They were noted as being slower to light from cold than conventional.[7] As the ashpan space beneath the grate was small, locomotives could only operate for a short time before needing to rake out this ashpan. On a main line railway this would have required a return to the engine shed.[3] On small narrow-gauge contractor lines, the ash would simply be dumped wherever convenient and so this was much less of a drawback.

Conical boilers

[edit]
Hohenzollern Nº 447

In 1888 theHohenzollern Locomotive Works delivered the first two narrow-gauge600 mm (1 ft 11+58 in)Feldbahn locomotives for thePrussian Army. These used a conical development of the launch boiler. A backplate of enlarged diameter and a greatly reduced smokebox tubeplate were fitted into a steeply conical shell. This was installed with the upper edge[i] of the cone horizontal. The purpose of the conical shape was to increase water depth over the furnace, the hottest part of the evaporative surface. The furnace and tubes were moved to the lower part of the shell, with the tubes running upwards parallel to the lower edge of the cone. A difficulty was the boiler's lack of steam space, requiring an enlarged dome, of almost as much capacity as the main shell.[8] As a major virtue of the launch boiler is the simplicity of its construction, rolling a conical shell and fitting a large dome represented a considerable increase in their complexity and cost.

These locomotives, and their boilers, were a complete failure. They were undersized and underpowered for the task, with tiny wheels prone to derailment on uneven track and (for the first 2-2-2 locomotive) limited adhesion from its single driver. Despite being some years after Heywood and the publication of hisMinimum Gauge Railways, they ignored almost all of Heywood's principles. The boilers lacked evaporative capacity and could not support sustained running.[8]

Lentz boiler

[edit]

A large launch-type boiler with acorrugated furnace, described as theLentz boiler, was fitted to the firstHeilmann steam-electric locomotive'La Fusée Electrique' of 1890.[9] The boiler design was German in origin. A similar boiler, the 'Vanderbilt' was used in the USA.[10]

Lancashire & Yorkshire Railway

[edit]
L&YR Class 30 with cylindrical furnace

TheLancashire and Yorkshire Railway suffered problems withfirebox stays, leading to aboiler explosion with an0-8-0'Class 30' nearKnottingley in 1901[11][12] Their Chief Mechanical EngineerHenry Hoy, sought to avoid the problems of the stayed firebox altogether and so developed an alternative boiler and firebox. This used a corrugated tubular furnace and cylindrical outer firebox, as for the Lentz.[10] Such corrugated furnaces were already in widespread use locally, with theLancashire andGalloway stationary boilers of the Lancashire cotton mills and local makers already had several designs available. The furnace was also of steel, rather than thecopper used for fireboxes at this time.[10] Hoy's involvement was ironic, as a major cause of the original accident had been Hoy's invention of a new brass alloy for firebox stays, an inelastic alloy that turned out to have serious drawbacks.[12][13] One Class 30,396, was rebuilt in 1903 and 20 more were built new with this boiler.[12]

The boilers showed a number of drawbacks in service. They were slow to warm up after lighting, and the limited ashpan space limited their working time away from the shed. Both of these were as a result of the furnace heating area largely being shielded by the grate across it. It has been suggested that they would have been more successful with oil firing,[ii] as this would have allowed the whole furnace diameter to have been used and would have avoided ash build up.[7]

The new boiler design did not last long in service and the locomotives were rebuilt with conventional boilers after ten years.[iii][12] Hoy's successor,George Hughes, described these boilers unfavourably in papers read to theI. Mech E.[14][15]

NZR E class

[edit]
Corrugated furnace of the NZR E class
Boiler of the NZR E class

The singleNZRE class of 1906 was an experimentalVauclain compound articulated 2-6-6-0TMallet, intended for working theRimutaka Incline. Compounding encouraged the choice of the then remarkably high boiler pressure of 200 psi (14 bar; 1,400 kPa), which required a strong firebox construction. The NZR chief draughtsman G. A. Pearson chose a corrugated furnace design in a tapered boiler, similar to the Vanderbilt.

References

[edit]
Wikimedia Commons has media related toLaunch-type boilers.
  1. ^or 'generatrix'
  2. ^This was a modern development in boiler firing at the time, exemplified by the newDreadnought-class battleships.Holden on theGreat Eastern Railway was also experimenting with oil firing. However the L&YR was based in theLancashire Coalfield.
  3. ^The eight to ten year interval before rebuilding would be a typical service life for such a boiler. It indicates that the boilers were adequate, and were not withdrawn from service merely to replace them, but also that the experiment was not considered a success and so they were not continued with.
  1. ^Harris, K. N. (1974).Model Boilers and Boilermaking. MAP. p. 50.ISBN 0-85242-377-2.
  2. ^abcMosley, David; van Zeller, Peter (1986).Fifteen Inch Gauge Railways.David & Charles. p. 58.ISBN 0-7153-8694-8.
  3. ^abcHaigh, Alan J. (2013).Locomotive Boilers for the Twenty-first Century. Xpress Publishing. p. 48.ISBN 978-1-901056-47-1.
  4. ^"Marshall".Road Steam.
  5. ^"Marshall Britannia portable steam engine, 1914".Powerhouse Museum.
  6. ^Heywood, A.P. (1974) [1881, Derby: Bemrose].Minimum Gauge Railways. Turntable Enterprises.ISBN 0-902844-26-1.The boiler was of the launch type, a cylindrical shell with a cylindrical fire-box terminating in tubes. This pattern of boiler, though giving less heating surface for its size than one of ordinary locomotive design, has the great merit of having no fire box projecting below the barrel, thus enabling the over-hang of the frame beyond the wheel-base to be equalized at each end, a matter of the first importance in small tank engines. Its low first cost and the ease with which it can be kept in order are additional advantages. So well was I satisfied with the working, that in the four boilers since designed for my locomotives I have adhered to the original plan, which was copied from some shunting engines made by Mr. Ramsbottom for the London and North Western Railway. I go so far as to think that, without getting rid of a depending fire-box, no really satisfactory tank engine can be constructed for a small-gauge railway unless idle wheels are introduced, a proceeding that cannot too strongly be deprecated. The gradients, which are almost invariably the concomitants of these small lines, make it essential that the whole of the available weight should be utilized for adhesion.
  7. ^abHaigh (2013), pp. 39–40.
  8. ^abFach, Rüdiger; Krall, Günter (2002).Heeresfeldbahnen der Kaiserzeit. Kenning.ISBN 3933613469.
  9. ^"Heilmann Locomotives".Loco locos. 19 Oct 2007.
  10. ^abcAhrons, E.L. (1966).The British Steam Railway Locomotive. Vol. I, to 1925.Ian Allan. p. 351.
  11. ^Hewison, Christian H. (1983).Locomotive Boiler Explosions. David and Charles. pp. 110–111.ISBN 0-7153-8305-1.
  12. ^abcdCook, A.F. (1999).Raising Steam on the LMS.RCTS. pp. 23–26.ISBN 0-901115-85-1.
  13. ^Hewison (1983), p. 111.
  14. ^Hughes, George (Feb 1906).Proc. Inst. Mech. Eng.{{cite journal}}: CS1 maint: untitled periodical (link)
  15. ^Hughes, George (July 1909).Proc. Inst. Mech. Eng.{{cite journal}}: CS1 maint: untitled periodical (link)
Simple boilers
Fire-tube boilers
Water-tube boilers
Electric boilers
Boiler components
Boiler peripherals
Operating cycle
Valves
Valves
Valve gear
Mechanisms
Boilers
Simple boilers
Fire-tube boilers
Water-tube boilers
Boiler feed
Cylinder
Condenser
Other
History
Precursors
Newcomen engine
Watt engine
Beam
Rotative beam
High-pressure
Compound
Murray
High-speed
See also
Retrieved from "https://en.wikipedia.org/w/index.php?title=Launch-type_boiler&oldid=1282372172#Bagnall_boiler"
Categories:
Hidden categories:

[8]ページ先頭

©2009-2025 Movatter.jp