Circulating water plant

From Wikipedia, the free encyclopedia
Industrial equipment
This article has multiple issues. Please helpimprove it or discuss these issues on thetalk page.(Learn how and when to remove these messages)
This article includes a list ofgeneral references, butit lacks sufficient correspondinginline citations. Please help toimprove this article byintroducing more precise citations.(June 2015) (Learn how and when to remove this message)
icon
This articleneeds additional citations forverification. Please helpimprove this article byadding citations to reliable sources. Unsourced material may be challenged and removed.
Find sources: "Circulating water plant" – news ·newspapers ·books ·scholar ·JSTOR
(June 2015) (Learn how and when to remove this message)
(Learn how and when to remove this message)

Acirculating water plant orcirculating water system is an arrangement of flow of water infossil-fuel power stations,chemical plants, andoil refineries. Such a system is required because variousindustrial process plants usesheat exchangers, and also foractive fire protection measures. In chemical plants, for example incaustic soda production, water is needed in bulk for the preparation ofbrine. The circulating water system in any plant consists of acirculator pump, which develops an appropriatehydraulic head, andpipelines to circulate the water in the entire plant.

System description

[edit]

Circulating water pumps

[edit]
See also:Circulator pump

Circulating water systems are normally of the wet-pit type, but for sea-water circulation, both the wet-pit type and the concrete-volute type are employed.[1] In some industries, one or two standby pumps are also connected parallel to CW pumps. It is recommended that these pumps must be constantly driven by constant-speedsquirrel-cageinduction motors. CW pumps are designed as per IS:9137,[2][3] standards of the Hydraulic Institute, USA, or equivalent.

Cooling tower

[edit]
See also:Cooling tower

In the present era, mechanical induced draft–type cooling towers are employed in cooling of water. Performance testing of cooling towers (both IDCT and NDCT) shall be carried out as per ATC-105[4] at a time when the atmospheric conditions are within the permissible limits of deviation from the design conditions. As guidelines ofCentral Electricity Authority, two mechanical-draftcooling towers or one natural-draft cooling tower must be established for each 500 MW unit in power plants. The cooling towers are designed as per Cooling Tower Institute codes.

CW treatment system

[edit]

Some coastal power stations or chemical plants intake water from sea forcondenser cooling. They use either closed-cycle cooling by using cooling towers or once-through cooling. The selection of the type of system is based on the thermal pollution effect on seawater and techno-economics based on the distance of the power station from the coast and the cost of pumping seawater.

Mechanical description of CW plants

[edit]

Source:[5]

  • Five (4 working + 1 standby) circulating water pumps of vertical wet-pit type, mixed-flow design and self-water-lubricated, along with motors and associated accessories.
  • Electro-hydraulically operatedbutterfly valve (with actuators), isolating butterfly valve, and rubberexpansion joints at the discharge of each pump. Electrically operated butterfly valves for interconnection of standby pumps to operate as common standby for both units.
  • One CW recirculation line for each unit, suitable for handling a flow of 50% of one CW pump flow with electrically operated butterfly valve (with actuators).
  • Complete piping, including discharge piping/header of CW pumps, a CW duct from the CW pumphouse to the condensers, and from the condensers to the cooling towers, blowdown piping (up to an ash-handling plant and central monitoring basin of ETP[clarification needed]), fittings & valves and other accessories as required.
  • EOT[clarification needed] crane for handling & maintenance of CW pumps and monorail and electrically operated pendant control hoist arrangement[clarification needed] for maintenance of stoplog gates andtrash racks.
  • One trash rack for the CW pumphouse bay and two stop logs for the CW pumphouse.
  • Air release valves, with isolation valves, in CW piping as per the system requirement.
  • Hydraulic transient analysis of the CW system.
  • CW pump model study and CW pumphouse/sump model studies as required.

Codes and standards

[edit]

Source:[6]

Sr No.IS CODESpecification
1IS: 804Rectangular pressed steel tanks
2IS: 1239Mild steel tubes, tubular, & other wrought steel fittings
3IS: 1520Horizontal, centrifugal pumps for clear, cold fresh water
4IS: 1536Centrifugally cast (spun) iron pressure pipes for water, gas, and

sewage

5IS: 1537Vertically cast iron pressure pipes for water, gas, and sewage
6IS: 1710Vertical turbine pumps for clear, cold fresh water
7IS: 2002Steel plates for boilers
8IS: 2062Structural steel (Fusion welding quality)
9IS: 2594Horizontal mild-steel welded storage tanks
10IS: 2825Code for unfired pressure vessels
11IS: 3589Electrical welded pipes for water, gas, & sewage (200 to

2000mm)

12IS: 3832Hand-operated chain pulley block
13IS: 4682Code of practice for lining of vessels and equipment for

chemical processes-rubber lining

14IS: 5120Technical requirements for rotodynamic special-purpose

pumps

15IS: 5639Pumps handling chemicals and corrosive liquids
16IS: 5659Pumps for process water
17IS: 6393Steel pipe flanges
18IS: 6547Electric chain hoist
19BS: 5155Cast-iron & carbon-steel butterfly valves for general purpose
20AWWA-C-504Rubber seated butterfly valves

References

[edit]
  1. ^Standard Design Criteria/Guidelines for Balance of Plant for Thermal Power Project 2 X (500MW or above) Section- 6 (Circulating Water System)
  2. ^IS 9137 (1978): Code for acceptance test for centrifugal, mixed flow and axial pumps - Class C [MED 20: Mechanical Engineering]
  3. ^CODE FOR ACCEPTANCE TESTS FOR CENTRIFUGAL, MIXED FLOW AND AXIAL PUMPS—CLASS C (Indian Standard 9137 - 1978)(PDF), Bureau of Indian Standards, June 1997, retrieved31 January 2026
  4. ^Standard Design Criteria/Guidelines for Balance of Plant for Thermal PowerProject 2 X (500MW or above) Section- 6 (Circulating Water System), Pg 6-6, Section 6.4.3.
  5. ^Standard Design Criteria/Guidelines for Balance of Plant for Thermal Power Project 2 X (500MW or above) Section- 6 (Circulating Water System), ANNEXURE 6A, Pg 6-17.
  6. ^Standard Design Criteria/Guidelines for Balance of Plant for Thermal Power Project 2 X (500MW or above) Section- 6 (Circulating Water System), Pg 6-15, Section ^.7.

External links