Optica Article

Maximum-likelihood curve-fitting scheme for experiments with pulsed lasers subject to intensity fluctuations

Thomas Metz, Joachim Walewski, and Clemens F. Kaminski

Author Information
Author Affiliations

Thomas Metz,Joachim Walewski,and Clemens F. Kaminski

T. Metz (thomas.metz@forbrf.lth.se) and J. Walewski are with the Division of Combustion Physics, Lund Institute of Technology, P.O. Box 118, SE-221 00 Lund, Sweden.

C. F. Kaminski is with the Department of Chemical Engineering, University of Cambridge, Pembroke Street, Cambridge CB2 3RA, UK.

Not Accessible

Your library or personal account may give you access

  • History
    • Original Manuscript: December 10, 2001
    • Revised Manuscript: November 3, 2002
    • Published: March 20, 2003

Abstract

Evaluation schemes, e.g., least-squares fitting, are not generally applicable to any types of experiments. If the evaluation schemes were not derived from a measurement model that properly described the experiment to be evaluated, poorer precision or accuracy than attainable from the measured data could result. We outline ways in which statistical data evaluation schemes should be derived for all types of experiment, and we demonstrate them for laser-spectroscopic experiments, in which pulse-to-pulse fluctuations of the laser power cause correlated variations of laser intensity and generated signal intensity. The method of maximum likelihood is demonstrated in the derivation of an appropriate fitting scheme for this type of experiment. Statistical data evaluation contains the following steps. First, one has to provide a measurement model that considers statistical variation of all enclosed variables. Second, an evaluation scheme applicable to this particular model has to be derived or provided. Third, the scheme has to be characterized in terms of accuracy and precision. A criterion for accepting an evaluation scheme is that it have accuracy and precision as close as possible to the theoretical limit. The fitting scheme derived for experiments with pulsed lasers is compared to well-established schemes in terms of fitting power and rational functions. The precision is found to be as much as three times better than for simple least-squares fitting. Our scheme also suppresses the bias on the estimated model parameters that other methods may exhibit if they are applied in an uncritical fashion. We focus on experiments in nonlinear spectroscopy, but the fitting scheme derived is applicable in many scientific disciplines.

© 2003 Optical Society of America

Full Article  | PDF Article
More Like This
A maximum likelihood approach to the inverse problem of scatterometry

Mark-Alexander Henn, Hermann Gross, Frank Scholze, Matthias Wurm, Clemens Elster, and Markus Bär
Opt. Express20(12) 12771-12786 (2012)

Simple Monte Carlo methods to estimate the spectra evaluation error in differential-optical-absorption spectroscopy

Martin Hausmann, Uwe Brandenburger, Theo Brauers, and Hans-Peter Dorn
Appl. Opt.38(3) 462-475 (1999)

Maximum-likelihood methods in wavefront sensing: stochastic models and likelihood functions

Harrison H. Barrett, Christopher Dainty, and David Lara
J. Opt. Soc. Am. A24(2) 391-414 (2007)

Experimental estimation of the spatial statistics of turbulence-induced index of refraction fluctuations in the upper atmosphere

Jeffrey T. Beyer, Michael C. Roggemann, L. John Otten, Timothy J. Schulz, Timothy C. Havens, and Wade W. Brown
Appl. Opt.42(6) 908-921 (2003)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Figures (8)

You do not have subscription access to this journal. Figure files are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Tables (1)

You do not have subscription access to this journal. Article tables are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Equations (32)

You do not have subscription access to this journal. Equations are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Journal Home
About
Application Notes
Issues in Progress
Current Issue
All Issues
Early Posting
Feature Issues