Movatterモバイル変換


[0]ホーム

URL:


About:Euglobulin lysis time

An Entity of Type:cricketer,from Named Graph:http://dbpedia.org,within Data Space:dbpedia.org

The euglobulin lysis time (ELT) is a test that measures overall fibrinolysis. The test is performed by mixing citrated platelet-poor plasma with acid in a glass test tube. This acidification causes the precipitation of certain clotting factors in a complex called the euglobulin fraction. The euglobulin fraction contains the important fibrinolytic factors fibrinogen, PAI-1, tissue plasminogen activator (tPA), plasminogen, and to a lesser extent α2-antiplasmin. The euglobulin fraction also contains factor VIII.

PropertyValue
dbo:abstract
  • The euglobulin lysis time (ELT) is a test that measures overall fibrinolysis. The test is performed by mixing citrated platelet-poor plasma with acid in a glass test tube. This acidification causes the precipitation of certain clotting factors in a complex called the euglobulin fraction. The euglobulin fraction contains the important fibrinolytic factors fibrinogen, PAI-1, tissue plasminogen activator (tPA), plasminogen, and to a lesser extent α2-antiplasmin. The euglobulin fraction also contains factor VIII. After precipitation, the euglobulin fraction is resuspended in a borate solution. Clotting is then activated by the addition of calcium chloride at 37 °C. Historically, subsequent amount of fibrinolysis was determined by eye, by observing the clot within the test tube at ten-minute intervals until complete lysis had occurred. Newer automated methods have also been developed. These methods use the same principle as the older technique, but use a spectrophotometer to track clot lysis as a function of optical density. (en)
  • Le temps de lyse de l'euglobuline est un test qui mesure la fibrinolyse globale. L'essai est effectué en mélangeant du plasma pauvre en plaquettes citratées avec de l'acide dans un tube à essai. Cette acidification provoque la précipitation de certains facteurs de coagulation dans un complexe appelé fraction euglobuline. La fraction d'euglobuline contient les facteurs fibrinolytiques importants fibrinogène, PAI-1, activateur tissulaire du plasminogène (tPA), plasminogène, et dans une moindre mesure alpha 2-antiplasmin. La fraction d'euglobuline contient également du facteur VIII. Après précipitation, la fraction d'euglobuline est remise en suspension dans une solution de borate. La coagulation est ensuite activée par addition de chlorure de calcium à 37 °C. Historiquement, la quantité subséquente de fibrinolyse était déterminée à l'œil nu, en observant le caillot dans l'éprouvette à intervalles de dix minutes jusqu'à ce que la lyse complète ait eu lieu. Les nouvelles techniques automatisées utilisent le même principe que l'ancienne technique, mais utilisent un spectrophotomètre pour suivre la lyse du caillot en fonction de la densité optique. (fr)
dbo:wikiPageID
  • 15861652 (xsd:integer)
dbo:wikiPageLength
  • 2312 (xsd:nonNegativeInteger)
dbo:wikiPageRevisionID
  • 1084081866 (xsd:integer)
dbo:wikiPageWikiLink
dbp:name
  • Euglobulin lysis time (en)
dbp:testOf
  • Overall fibrinolysis (en)
dbp:wikiPageUsesTemplate
dcterms:subject
gold:hypernym
rdf:type
rdfs:comment
  • The euglobulin lysis time (ELT) is a test that measures overall fibrinolysis. The test is performed by mixing citrated platelet-poor plasma with acid in a glass test tube. This acidification causes the precipitation of certain clotting factors in a complex called the euglobulin fraction. The euglobulin fraction contains the important fibrinolytic factors fibrinogen, PAI-1, tissue plasminogen activator (tPA), plasminogen, and to a lesser extent α2-antiplasmin. The euglobulin fraction also contains factor VIII. (en)
  • Le temps de lyse de l'euglobuline est un test qui mesure la fibrinolyse globale. L'essai est effectué en mélangeant du plasma pauvre en plaquettes citratées avec de l'acide dans un tube à essai. Cette acidification provoque la précipitation de certains facteurs de coagulation dans un complexe appelé fraction euglobuline. La fraction d'euglobuline contient les facteurs fibrinolytiques importants fibrinogène, PAI-1, activateur tissulaire du plasminogène (tPA), plasminogène, et dans une moindre mesure alpha 2-antiplasmin. La fraction d'euglobuline contient également du facteur VIII. (fr)
rdfs:label
  • Euglobulin lysis time (en)
  • Temps de lyse de l'euglobuline (fr)
owl:sameAs
prov:wasDerivedFrom
foaf:isPrimaryTopicOf
isdbo:wikiPageDisambiguates of
isdbo:wikiPageWikiLink of
isfoaf:primaryTopic of
Powered by OpenLink Virtuoso   This material is Open Knowledge    W3C Semantic Web Technology    This material is Open Knowledge   Valid XHTML + RDFa
This content was extracted fromWikipedia and is licensed under theCreative Commons Attribution-ShareAlike 3.0 Unported License

[8]ページ先頭

©2009-2025 Movatter.jp